H6/p5 fit — Precision interference

ISO 286 hole-basis interference fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 H6/p5Interference fit
UpperLowerMaxMin
Hole H6+0.013025.01325.000
Shaft p5+0.031+0.02225.03125.022
Max interference
0.031 mm
Min interference
0.009 mm
Mean
−0.020 mm

Fit diagram (µm · zero line = nominal)

0µmHole H6Shaft p5Interference+13+31+22min −9max −31
Hole tolerance zoneShaft tolerance zoneInterference

About H6/p5

Precision locational press fit, e.g. bushes in instrument housings.

At Ø25 mm the hole H6 measures 0 mm to +0.013 mm and the shaft p5 +0.022 mm to +0.031 mm, giving an interference of 0.009 mm to 0.031 mm.

How the limits are calculated

Hole H6: fundamental deviation EI = 0, standard tolerance IT6 = 13 µm for 18–30 mm. Shaft p5: fundamental deviation ei = 22 µm, IT5 = 9 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

H6/p5 limits by size range

Size (mm)Hole H6Shaft p5
≤ 3+0.006 / 0+0.010 / +0.006
3 – 6+0.008 / 0+0.017 / +0.012
6 – 10+0.009 / 0+0.021 / +0.015
10 – 18+0.011 / 0+0.026 / +0.018
18 – 30+0.013 / 0+0.031 / +0.022
30 – 50+0.016 / 0+0.037 / +0.026
50 – 80+0.019 / 0+0.045 / +0.032
80 – 120+0.022 / 0+0.052 / +0.037
120 – 180+0.025 / 0+0.061 / +0.043
180 – 250+0.029 / 0+0.070 / +0.050
250 – 315+0.032 / 0+0.079 / +0.056
315 – 400+0.036 / 0+0.087 / +0.062
400 – 500+0.040 / 0+0.095 / +0.068

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.

Related fits