H6/n5 fit — Precision interference

ISO 286 hole-basis interference fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 H6/n5Interference fit
UpperLowerMaxMin
Hole H6+0.013025.01325.000
Shaft n5+0.024+0.01525.02425.015
Max interference
0.024 mm
Min interference
0.002 mm
Mean
−0.013 mm

Fit diagram (µm · zero line = nominal)

0µmHole H6Shaft n5Interference+13+24+15min −2max −24
Hole tolerance zoneShaft tolerance zoneInterference

About H6/n5

Light press fit for precision parts that must not move.

At Ø25 mm the hole H6 measures 0 mm to +0.013 mm and the shaft n5 +0.015 mm to +0.024 mm, giving an interference of 0.002 mm to 0.024 mm.

How the limits are calculated

Hole H6: fundamental deviation EI = 0, standard tolerance IT6 = 13 µm for 18–30 mm. Shaft n5: fundamental deviation ei = 15 µm, IT5 = 9 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

H6/n5 limits by size range

Size (mm)Hole H6Shaft n5
≤ 3+0.006 / 0+0.008 / +0.004
3 – 6+0.008 / 0+0.013 / +0.008
6 – 10+0.009 / 0+0.016 / +0.010
10 – 18+0.011 / 0+0.020 / +0.012
18 – 30+0.013 / 0+0.024 / +0.015
30 – 50+0.016 / 0+0.028 / +0.017
50 – 80+0.019 / 0+0.033 / +0.020
80 – 120+0.022 / 0+0.038 / +0.023
120 – 180+0.025 / 0+0.045 / +0.027
180 – 250+0.029 / 0+0.051 / +0.031
250 – 315+0.032 / 0+0.057 / +0.034
315 – 400+0.036 / 0+0.062 / +0.037
400 – 500+0.040 / 0+0.067 / +0.040

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.