H6/k5 fit — Precision transition

ISO 286 hole-basis transition fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 H6/k5Transition fit
UpperLowerMaxMin
Hole H6+0.013025.01325.000
Shaft k5+0.011+0.00225.01125.002
Max clearance
0.011 mm
Max interference
0.011 mm
Mean
0 mm

Fit diagram (µm · zero line = nominal)

0µmHole H6Shaft k5Clearance+13+11+2max +11min −11
Hole tolerance zoneShaft tolerance zoneClearanceInterference

About H6/k5

Precision push fit, e.g. ball-bearing inner rings in instruments.

At Ø25 mm the hole H6 measures 0 mm to +0.013 mm and the shaft k5 +0.002 mm to +0.011 mm, giving between 0.011 mm interference and 0.011 mm clearance.

How the limits are calculated

Hole H6: fundamental deviation EI = 0, standard tolerance IT6 = 13 µm for 18–30 mm. Shaft k5: fundamental deviation ei = 2 µm, IT5 = 9 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

H6/k5 limits by size range

Size (mm)Hole H6Shaft k5
≤ 3+0.006 / 0+0.004 / 0
3 – 6+0.008 / 0+0.006 / +0.001
6 – 10+0.009 / 0+0.007 / +0.001
10 – 18+0.011 / 0+0.009 / +0.001
18 – 30+0.013 / 0+0.011 / +0.002
30 – 50+0.016 / 0+0.013 / +0.002
50 – 80+0.019 / 0+0.015 / +0.002
80 – 120+0.022 / 0+0.018 / +0.003
120 – 180+0.025 / 0+0.021 / +0.003
180 – 250+0.029 / 0+0.024 / +0.004
250 – 315+0.032 / 0+0.027 / +0.004
315 – 400+0.036 / 0+0.029 / +0.004
400 – 500+0.040 / 0+0.032 / +0.005

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.