H6/h5 fit — Precision locational fit

ISO 286 hole-basis clearance fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 H6/h5Clearance fit
UpperLowerMaxMin
Hole H6+0.013025.01325.000
Shaft h50−0.00925.00024.991
Max clearance
0.022 mm
Min clearance
0.000 mm
Mean
+0.011 mm

Fit diagram (µm · zero line = nominal)

0µmHole H6Shaft h5Clearance+13−9max +22min 0
Hole tolerance zoneShaft tolerance zoneClearance

About H6/h5

Precision parts located by the fit alone and assembled by hand, e.g. gauges and instrument components.

At Ø25 mm the hole H6 measures 0 mm to +0.013 mm and the shaft h5 −0.009 mm to 0 mm, giving a clearance of 0.000 mm to 0.022 mm.

How the limits are calculated

Hole H6: fundamental deviation EI = 0, standard tolerance IT6 = 13 µm for 18–30 mm. Shaft h5: fundamental deviation es = 0, IT5 = 9 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

H6/h5 limits by size range

Size (mm)Hole H6Shaft h5
≤ 3+0.006 / 00 / −0.004
3 – 6+0.008 / 00 / −0.005
6 – 10+0.009 / 00 / −0.006
10 – 18+0.011 / 00 / −0.008
18 – 30+0.013 / 00 / −0.009
30 – 50+0.016 / 00 / −0.011
50 – 80+0.019 / 00 / −0.013
80 – 120+0.022 / 00 / −0.015
120 – 180+0.025 / 00 / −0.018
180 – 250+0.029 / 00 / −0.020
250 – 315+0.032 / 00 / −0.023
315 – 400+0.036 / 00 / −0.025
400 – 500+0.040 / 00 / −0.027

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.