K7/h6 fit — Locational transition (shaft basis)

ISO 286 shaft-basis transition fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 K7/h6Transition fit
UpperLowerMaxMin
Hole K7+0.006−0.01525.00624.985
Shaft h60−0.01325.00024.987
Max clearance
0.019 mm
Max interference
0.015 mm
Mean
+0.002 mm

Fit diagram (µm · zero line = nominal)

0µmHole K7Shaft h6Clearance+6−15−13max +19min −15
Hole tolerance zoneShaft tolerance zoneClearanceInterference

About K7/h6

Shaft-basis equivalent of H7/k6, e.g. ball-bearing outer rings in housings.

At Ø25 mm the hole K7 measures −0.015 mm to +0.006 mm and the shaft h6 −0.013 mm to 0 mm, giving between 0.015 mm interference and 0.019 mm clearance.

How the limits are calculated

Hole K7: fundamental deviation ES/EI per ISO 286-1 Table 2, standard tolerance IT7 = 21 µm for 18–30 mm. Shaft h6: fundamental deviation es = 0, IT6 = 13 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

K7/h6 limits by size range

Size (mm)Hole K7Shaft h6
≤ 30 / −0.0100 / −0.006
3 – 6+0.003 / −0.0090 / −0.008
6 – 10+0.005 / −0.0100 / −0.009
10 – 18+0.006 / −0.0120 / −0.011
18 – 30+0.006 / −0.0150 / −0.013
30 – 50+0.007 / −0.0180 / −0.016
50 – 80+0.009 / −0.0210 / −0.019
80 – 120+0.010 / −0.0250 / −0.022
120 – 180+0.012 / −0.0280 / −0.025
180 – 250+0.013 / −0.0330 / −0.029
250 – 315+0.016 / −0.0360 / −0.032
315 – 400+0.017 / −0.0400 / −0.036
400 – 500+0.018 / −0.0450 / −0.040

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.