JS7/h6 fit — Locational transition (shaft basis)
ISO 286 shaft-basis transition fit. Enter a nominal size to get the limits.
Unit
Result
Ø25.000 JS7/h6Transition fit
| Upper | Lower | Max | Min | Tol. | |
|---|---|---|---|---|---|
| Hole JS7 | +0.0105 | −0.0105 | 25.0105 | 24.9895 | |
| Shaft h6 | 0 | −0.013 | 25.000 | 24.987 |
- Max clearance
- 0.0235 mm
- Max interference
- 0.0105 mm
- Mean
- +0.0065 mm
Fit diagram (µm · zero line = nominal)
Hole tolerance zoneShaft tolerance zoneClearanceInterference
About JS7/h6
Shaft-basis equivalent of H7/js6.
At Ø25 mm the hole JS7 measures −0.0105 mm to +0.0105 mm and the shaft h6 −0.013 mm to 0 mm, giving between 0.0105 mm interference and 0.0235 mm clearance.
How the limits are calculated
Hole JS7: fundamental deviation ES/EI per ISO 286-1 Table 2, standard tolerance IT7 = 21 µm for 18–30 mm. Shaft h6: fundamental deviation es = 0, IT6 = 13 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.
JS7/h6 limits by size range
| Size (mm) | Hole JS7 | Shaft h6 | Clearance min | Clearance max |
|---|---|---|---|---|
| ≤ 3 | +0.005 / −0.005 | 0 / −0.006 | −0.005 | +0.011 |
| 3 – 6 | +0.006 / −0.006 | 0 / −0.008 | −0.006 | +0.014 |
| 6 – 10 | +0.0075 / −0.0075 | 0 / −0.009 | −0.0075 | +0.0165 |
| 10 – 18 | +0.009 / −0.009 | 0 / −0.011 | −0.009 | +0.020 |
| 18 – 30 | +0.0105 / −0.0105 | 0 / −0.013 | −0.0105 | +0.0235 |
| 30 – 50 | +0.0125 / −0.0125 | 0 / −0.016 | −0.0125 | +0.0285 |
| 50 – 80 | +0.015 / −0.015 | 0 / −0.019 | −0.015 | +0.034 |
| 80 – 120 | +0.0175 / −0.0175 | 0 / −0.022 | −0.0175 | +0.0395 |
| 120 – 180 | +0.020 / −0.020 | 0 / −0.025 | −0.020 | +0.045 |
| 180 – 250 | +0.023 / −0.023 | 0 / −0.029 | −0.023 | +0.052 |
| 250 – 315 | +0.026 / −0.026 | 0 / −0.032 | −0.026 | +0.058 |
| 315 – 400 | +0.0285 / −0.0285 | 0 / −0.036 | −0.0285 | +0.0645 |
| 400 – 500 | +0.0315 / −0.0315 | 0 / −0.040 | −0.0315 | +0.0715 |
Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.