F7/h6 fit — Close running fit (shaft basis)

ISO 286 shaft-basis clearance fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 F7/h6Clearance fit
UpperLowerMaxMin
Hole F7+0.041+0.02025.04125.020
Shaft h60−0.01325.00024.987
Max clearance
0.054 mm
Min clearance
0.020 mm
Mean
+0.037 mm

Fit diagram (µm · zero line = nominal)

0µmHole F7Shaft h6Clearance+41+20−13max +54min +20
Hole tolerance zoneShaft tolerance zoneClearance

About F7/h6

Shaft-basis equivalent of H7/f7.

At Ø25 mm the hole F7 measures +0.020 mm to +0.041 mm and the shaft h6 −0.013 mm to 0 mm, giving a clearance of 0.020 mm to 0.054 mm.

How the limits are calculated

Hole F7: fundamental deviation ES/EI per ISO 286-1 Table 2, standard tolerance IT7 = 21 µm for 18–30 mm. Shaft h6: fundamental deviation es = 0, IT6 = 13 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

F7/h6 limits by size range

Size (mm)Hole F7Shaft h6
≤ 3+0.016 / +0.0060 / −0.006
3 – 6+0.022 / +0.0100 / −0.008
6 – 10+0.028 / +0.0130 / −0.009
10 – 18+0.034 / +0.0160 / −0.011
18 – 30+0.041 / +0.0200 / −0.013
30 – 50+0.050 / +0.0250 / −0.016
50 – 80+0.060 / +0.0300 / −0.019
80 – 120+0.071 / +0.0360 / −0.022
120 – 180+0.083 / +0.0430 / −0.025
180 – 250+0.096 / +0.0500 / −0.029
250 – 315+0.108 / +0.0560 / −0.032
315 – 400+0.119 / +0.0620 / −0.036
400 – 500+0.131 / +0.0680 / −0.040

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.