H9/h9 fit — Locational clearance
ISO 286 hole-basis clearance fit. Enter a nominal size to get the limits.
Result
| Upper | Lower | Max | Min | Tol. | |
|---|---|---|---|---|---|
| Hole H9 | +0.052 | 0 | 25.052 | 25.000 | |
| Shaft h9 | 0 | −0.052 | 25.000 | 24.948 |
- Max clearance
- 0.104 mm
- Min clearance
- 0.000 mm
- Mean
- +0.052 mm
Fit diagram (µm · zero line = nominal)
About H9/h9
Parts that assemble freely and are located by other means; general non-precision positioning.
At Ø25 mm the hole H9 measures 0 mm to +0.052 mm and the shaft h9 −0.052 mm to 0 mm, giving a clearance of 0.000 mm to 0.104 mm.
How the limits are calculated
Hole H9: fundamental deviation EI = 0, standard tolerance IT9 = 52 µm for 18–30 mm. Shaft h9: fundamental deviation es = 0, IT9 = 52 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.
H9/h9 limits by size range
| Size (mm) | Hole H9 | Shaft h9 | Clearance min | Clearance max |
|---|---|---|---|---|
| ≤ 3 | +0.025 / 0 | 0 / −0.025 | 0 | +0.050 |
| 3 – 6 | +0.030 / 0 | 0 / −0.030 | 0 | +0.060 |
| 6 – 10 | +0.036 / 0 | 0 / −0.036 | 0 | +0.072 |
| 10 – 18 | +0.043 / 0 | 0 / −0.043 | 0 | +0.086 |
| 18 – 30 | +0.052 / 0 | 0 / −0.052 | 0 | +0.104 |
| 30 – 50 | +0.062 / 0 | 0 / −0.062 | 0 | +0.124 |
| 50 – 80 | +0.074 / 0 | 0 / −0.074 | 0 | +0.148 |
| 80 – 120 | +0.087 / 0 | 0 / −0.087 | 0 | +0.174 |
| 120 – 180 | +0.100 / 0 | 0 / −0.100 | 0 | +0.200 |
| 180 – 250 | +0.115 / 0 | 0 / −0.115 | 0 | +0.230 |
| 250 – 315 | +0.130 / 0 | 0 / −0.130 | 0 | +0.260 |
| 315 – 400 | +0.140 / 0 | 0 / −0.140 | 0 | +0.280 |
| 400 – 500 | +0.155 / 0 | 0 / −0.155 | 0 | +0.310 |
Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.