H9/h9 fit — Locational clearance

ISO 286 hole-basis clearance fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 H9/h9Clearance fit
UpperLowerMaxMin
Hole H9+0.052025.05225.000
Shaft h90−0.05225.00024.948
Max clearance
0.104 mm
Min clearance
0.000 mm
Mean
+0.052 mm

Fit diagram (µm · zero line = nominal)

0µmHole H9Shaft h9Clearance+52−52max +104min 0
Hole tolerance zoneShaft tolerance zoneClearance

About H9/h9

Parts that assemble freely and are located by other means; general non-precision positioning.

At Ø25 mm the hole H9 measures 0 mm to +0.052 mm and the shaft h9 −0.052 mm to 0 mm, giving a clearance of 0.000 mm to 0.104 mm.

How the limits are calculated

Hole H9: fundamental deviation EI = 0, standard tolerance IT9 = 52 µm for 18–30 mm. Shaft h9: fundamental deviation es = 0, IT9 = 52 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

H9/h9 limits by size range

Size (mm)Hole H9Shaft h9
≤ 3+0.025 / 00 / −0.025
3 – 6+0.030 / 00 / −0.030
6 – 10+0.036 / 00 / −0.036
10 – 18+0.043 / 00 / −0.043
18 – 30+0.052 / 00 / −0.052
30 – 50+0.062 / 00 / −0.062
50 – 80+0.074 / 00 / −0.074
80 – 120+0.087 / 00 / −0.087
120 – 180+0.100 / 00 / −0.100
180 – 250+0.115 / 00 / −0.115
250 – 315+0.130 / 00 / −0.130
315 – 400+0.140 / 00 / −0.140
400 – 500+0.155 / 00 / −0.155

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.

Related fits