C11/h11 fit — Loose running fit (shaft basis)

ISO 286 shaft-basis clearance fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 C11/h11Clearance fit
UpperLowerMaxMin
Hole C11+0.240+0.11025.24025.110
Shaft h110−0.13025.00024.870
Max clearance
0.370 mm
Min clearance
0.110 mm
Mean
+0.240 mm

Fit diagram (µm · zero line = nominal)

0µmHole C11Shaft h11Clearance+240+110−130max +370min +110
Hole tolerance zoneShaft tolerance zoneClearance

About C11/h11

Shaft-basis equivalent of H11/c11 for plain drawn shafting.

At Ø25 mm the hole C11 measures +0.110 mm to +0.240 mm and the shaft h11 −0.130 mm to 0 mm, giving a clearance of 0.110 mm to 0.370 mm.

How the limits are calculated

Hole C11: fundamental deviation ES/EI per ISO 286-1 Table 2, standard tolerance IT11 = 130 µm for 18–30 mm. Shaft h11: fundamental deviation es = 0, IT11 = 130 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

C11/h11 limits by size range

Size (mm)Hole C11Shaft h11
≤ 3+0.120 / +0.0600 / −0.060
3 – 6+0.145 / +0.0700 / −0.075
6 – 10+0.170 / +0.0800 / −0.090
10 – 18+0.205 / +0.0950 / −0.110
18 – 30+0.240 / +0.1100 / −0.130
30 – 50+0.290 / +0.1300 / −0.160
50 – 80+0.340 / +0.1500 / −0.190
80 – 120+0.400 / +0.1800 / −0.220
120 – 180+0.480 / +0.2300 / −0.250
180 – 250+0.570 / +0.2800 / −0.290
250 – 315+0.650 / +0.3300 / −0.320
315 – 400+0.760 / +0.4000 / −0.360
400 – 500+0.880 / +0.4800 / −0.400

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.