P7/h6 fit — Locational interference (shaft basis)

ISO 286 shaft-basis interference fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 P7/h6Interference fit
UpperLowerMaxMin
Hole P7−0.014−0.03524.98624.965
Shaft h60−0.01325.00024.987
Max interference
0.035 mm
Min interference
0.001 mm
Mean
−0.018 mm

Fit diagram (µm · zero line = nominal)

0µmHole P7Shaft h6Interference−14−35−13min −1max −35
Hole tolerance zoneShaft tolerance zoneInterference

About P7/h6

Shaft-basis equivalent of H7/p6.

At Ø25 mm the hole P7 measures −0.035 mm to −0.014 mm and the shaft h6 −0.013 mm to 0 mm, giving an interference of 0.001 mm to 0.035 mm.

How the limits are calculated

Hole P7: fundamental deviation ES/EI per ISO 286-1 Table 2, standard tolerance IT7 = 21 µm for 18–30 mm. Shaft h6: fundamental deviation es = 0, IT6 = 13 µm. Clearance = hole − shaft, evaluated at both extremes. Values per ISO 286-1:2010.

P7/h6 limits by size range

Size (mm)Hole P7Shaft h6
≤ 3−0.006 / −0.0160 / −0.006
3 – 6−0.008 / −0.0200 / −0.008
6 – 10−0.009 / −0.0240 / −0.009
10 – 18−0.011 / −0.0290 / −0.011
18 – 30−0.014 / −0.0350 / −0.013
30 – 50−0.017 / −0.0420 / −0.016
50 – 80−0.021 / −0.0510 / −0.019
80 – 120−0.024 / −0.0590 / −0.022
120 – 180−0.028 / −0.0680 / −0.025
180 – 250−0.033 / −0.0790 / −0.029
250 – 315−0.036 / −0.0880 / −0.032
315 – 400−0.041 / −0.0980 / −0.036
400 – 500−0.045 / −0.1080 / −0.040

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size.